No hot water at all
On an electric unit, usually a failed upper element or a tripped high limit switch. On gas, often the pilot, thermocouple or gas valve. Check the breaker first, it is free.
Wichita Falls, Texas
No hot water, rusty water, or a tank that has started rumbling? Tell us what it is doing and we will connect you with a licensed plumber who works on water heaters in your part of Wichita Falls.
Takes about 30 seconds
Diagnosing It
Most water heater problems announce themselves clearly. Describing the symptom accurately on the phone helps the plumber arrive with the right part.
On an electric unit, usually a failed upper element or a tripped high limit switch. On gas, often the pilot, thermocouple or gas valve. Check the breaker first, it is free.
Classic sign of a failed lower element on an electric heater, or heavy sediment stealing tank capacity. Both are repairable if the tank itself is sound.
Sediment on the tank floor with water boiling underneath it. A flush may help if caught early. If it has gone on for years the damage is done.
If only the hot side is discoloured, the tank is corroding internally or the anode rod is spent. This one usually points at replacement.
Trace where it is coming from. A fitting or the relief valve is repairable. Weeping from the tank body itself means the tank is finished.
Either the valve has failed or the tank is genuinely over pressure or over temperature. Do not cap it or plug it. That valve is the safety device.
Usually a failed thermostat sticking the element on. Worth treating quickly if there are children or elderly people in the house.
Leave the building and call your gas utility from outside. Do not touch switches or the heater. That is a utility call before it is a plumbing call.
The Real Decision
This is where most of the money is decided, and where people get talked into the wrong thing in both directions. The age of the tank matters more than the symptom.
| Situation | Usually repair | Usually replace |
|---|---|---|
| Age of the unit | Under eight years old | Over ten years, especially past twelve here |
| Failed element or thermostat | Yes, if the tank is sound. A common, inexpensive repair | Only if the tank is also near end of life |
| Leaking | At a fitting, valve or connection | From the tank body itself. Nothing repairs a corroded tank |
| Rusty hot water | If it clears after a flush and an anode rod change | If it persists. The tank lining has gone |
| Heavy sediment | Flush it, if this is the first time and it is caught early | If it has rumbled for years and capacity is well down |
| Repeat repairs | First or second fault on a young unit | Third call out on the same heater. You are funding a replacement in instalments |
Ask the plumber for the age off the data plate before discussing the fix. The serial number encodes the manufacture date, and a straight answer there tells you which column you are in.
Local Factor
This is the single biggest difference between owning a water heater in Wichita Falls and owning one somewhere with soft water. It is worth understanding, because it changes what maintenance is worth doing.
If It Is Leaking Right Now
There is a valve on the cold inlet at the top of the unit. If it will not turn, shut off the main instead.
Electric: switch it off at the breaker. Gas: turn the control to pilot or off. An element firing in a draining tank will burn out.
If the relief valve is discharging, that is the safety device doing its job. Plugging it is genuinely dangerous. Leave it and get it looked at.
Questions
Manufacturers quote eight to twelve years, and that assumes reasonable water quality. Ours is hard, so scale builds on the elements and the tank floor and pulls that number down. A unit that has passed twelve years here has already beaten the local average. Once you are in that range, planning the replacement is cheaper and far less stressful than waiting for forty gallons to find your flooring.
Under eight years old with a failed element, thermostat or valve is usually worth repairing, and those are inexpensive parts. Over ten years old with rust in the hot water or water weeping from the tank body means replacement, because the tank itself is corroding and no repair addresses that. If you are on the third call out for the same heater, you are paying for a new one in instalments without getting one.
Sediment. Mineral scale settles on the tank floor, water gets trapped underneath it, and when that water boils it forces its way out through the layer. That is the popping. It also insulates the burner from the water it is supposed to heat, so the unit runs longer, costs more and stresses the steel. Caught early a flush helps. After years of it, the damage is already done.
If water is coming from the tank body itself, yes. That means the tank has corroded through and it holds forty gallons or more that will end up on your floor. Shut the water off to the heater, kill the power or set gas to pilot, and get someone out. Water at a fitting, a connection or the relief valve is less urgent and often repairable, but it still should not be left.
Yes, and noticeably. Wichita Falls water carries a heavy mineral load, and those minerals come out of solution when heated. On an electric unit they coat the elements, on a gas unit they blanket the tank floor. Either way the heater works harder for the same result. Annual flushing genuinely extends the life of the unit. A softener does more, and protects your fixtures and pipes at the same time.
Tankless units save space, never run out of hot water and last longer on paper. The catch locally is that hard water is harder on a tankless heat exchanger than on a tank, and most manufacturers require annual descaling to keep the warranty valid. If you will genuinely keep up that maintenance, tankless is a good choice. If you will not, a quality tank unit paired with a softener is the more realistic option here.
On a young unit that has been flushed regularly, yes, and it is a reasonable job for a confident homeowner. On an old unit that has never been flushed, be careful. The drain valve is often plastic and seized, sediment can block it half open, and you can end up unable to stop the flow. If your heater is over eight years old and has never been flushed, it is worth having a plumber do the first one.
A straight swap of a similar unit is usually a same day job once the plumber has the heater. Changing fuel type, moving the location, going tankless or bringing old connections up to current code all add time, and water heater replacement needs a City of Wichita Falls permit. If a contractor offers to skip the permit to save you money, that is a red flag worth walking away from.
Related
Burst pipes, sewer backups and water heater failures, 24 hours a day.
Galvanized and polybutylene replaced in PEX, fixed price and a written schedule.
Slow tubs, blocked kitchen lines and sewer clogs, cleared and camera checked.
A leaking tank holds forty gallons or more and it will not hold forever. Requests are taken around the clock, seven days a week.